Facade Systems
Exposed Fastener Rainscreen System
System Depth = 1” + Universe Continuous Insulation System (1” to 3” thick as indicated on drawings)
Joint Width = 3/8”
 
System Components:
1.    Trespa® Meteon® Panel
2.    Universe Aluminum J-Extrusion – Black Color
3.    Universe Aluminum Running Bond Extrusion – Black Color
4.    Extrusion Fastener
5.    Panel Fastener
6.    Continuous Insulation Horizontal Wide-Faced Hat Extrusion Framing
7.    Wide-Face Hat Framing Fastener; attaches through mineral wool to substrate
8.    Roxul® ComfortBoard™ CIS 11# Density Mineral Wool Insulation
9.    Air & Moisture Barrier
10.    Sheathing
11.    16 Gauge Min. Steel Stud
 
Notes:
•    Vertically attached.
•    Insulation (8) must be Roxul® ComfortBoard™ CIS 11# Density mineral wool in order to be NFPA-285 fire code compliant and provide the required rigidity for the framing to attach against. Foam plastic insulation triggers NFPA-285 fire code which requires a tested assembly.
•    Air & Moisture barrier (9) must be VaproShield® WallShield®, WrapShield®, RevealShield™, Cosella-Dorken Delta® Fassade-S, Delta® Foxx, Delta® Foxx-S, Tyvek® CommercialWrap®, Dow Corning DefendAir 200 or Momentive™ SEC2500-SilShield AWB if mineral wool is less than 2” thick; if mineral wool is thicker than 2” then other barriers may be used.
•    The framing (6) is not painted.
•    Painted and decorative panel fasteners (5) are available for a premium.